Welding Habitat
- Welding Safety Habitat Enclosure provides solutions for hot work activity for the oil and gas, especially for onshore and offshore facilities.
- Welding Safety Habitat Enclosure proof to be the best solution to save million of money by allowing hot work to be performed during platform ONLINE, instead of having shutdown for certain important maintenance work.
- Welding Safety Habitat Enclosure are designed with electrical equipment and manufacture positive pressure hot work welding habitats (overpressure enclosures) and applicable for Zone 1 or Zone 2 working area.
- It is the best solution to cater risk management and controlling issues when working in potentially explosive environments.
- Welding Safety Habitat Enclosure separating the ignition source and the hazardous area, allowing work to continue with radically reduces risk.
Welding Habit Specifications
Material | Fire Retardant, Silicone Coated Fiberglass | |
---|---|---|
Size Color | Orange/Blue | |
Standard Size | 1000mm x 1000mm, 1000mm x 2000mm | |
Thickness | 0.60-0.75mm | |
Application | High Temperature | |
Rated Voltage | 20-50 kV/mm | |
Heat Resistance (°C) | 300°C | |
Tensile Strength | 2300 x 1500 N/5cm | |
Approval Body | SIRIM INTERNATIONAL |
Material | PVC Antistatic Fabric | |
---|---|---|
GSM Weight | 470+_ 20 g/sqm | |
Thickness | 0.4 mm | |
Tensile Strength Warp | 300 N/5cm | |
Tensile Strength Weft | 350 N/5cm | |
Tear Strength Warp | 20 N | |
Tear Strength Weft | 40 N | |
Fire Resistant Coefficient | Fire-Resistant Grade B | |
Oxygen Index | >_ 30 | |
Surface Resistance | ≤2x10° | |
Temperature Range | -15°C to +80°C |
Туре | Axial Fan (Portable Ventilator Ex Type Motor) | |
---|---|---|
Brand | Sayi Electrical | |
Type of Approval | ATEX/Zone 1, Zone 2 | |
Approval Code | Presafe 16 ATEX, EN 60079—0:2012/A11: 2013 | |
Approval Body Name | PRESAFE | |
Mounting | Free Standing | |
Flow Rate | 3900/4620 m3/hours | |
Speed (RPM) | 2800/3300 | |
Voltage | 220-240 V | |
Ventilator | Flameproof | |
Frequency | 50/60 Hz | |
Watts | 500/550 | |
Weight | 19kg |
Туре | Floor Standing Alone |
---|---|
Function | Used In The Hazard Area Zone 1, Zone 2 (IEC Hazard Area Classification), Class 1, Division 2, Group B, C, D Area (NEC Hazard Area Classification) |
Ex-Marking | Exmd II BT3 |
Power Consumption | <5W |
Lowest Ambient Temperature | -45°C |
Input Voltage | AC380V/50HZ/3p |
Heating Capacity | 15 kw |
Rated Power | 15.7 W |
Rated Current | 41.3 A |
Air Flow | 8700 m3/h |
Protection Class | 20 |
Ducting | With Stainless Steel Material, 100 cm Length, 400mm Diameter |
Dimension | 800 x 1700 x 500 mm |
Net Weight | 70KG |
Service | Air and Non-Combustible Compatible Gases. Natural Gas Option Available. |
---|---|
Housing | Die Cast Aluminium Case and Bezel, with Acrylic Cover, Exterior Finish is Coated Gray |
Accuracy | +_ 2.5% Of Full Scale |
Pressure Limits | -70 to 100 kPa |
Temperature Limits | 20 to 140°F (-6.67°C to +60°C)k |
Size | 4" Diameter Dial Face |
Mounting Orientation | Diaphragm in Vertical Position |
Connections | 1/4" NPTF) High and Low Pressure Taps, Duplicated-One Pair Side and One Pair BacK |
Function | Room Temperature & Defrosting Temperature Input, Compressor Floodlight & Defrosting Output |
---|---|
Power Supply | 85-265V AC 50/60Hz |
Power Consumption | <5W |
Ambient Temperature | 0°C to 50°C |
Ambient Humidity | <80% |
Control Temperature Range | -40°C to +45°C |
Measuring Range | -40°C to +99°C |
Input Signal | 2 Loop NTC Thermistor (Thermal Resistor, For Room & Defrosting Temperature) |
Sampling Cycle | 0.15 |
Output | Relay Output, SSR Output |
Relay Output | Compressor Relay 10A/300V AC Fan/Defrosting 3A/220V AC |
Insulating Reshtance | >100M DC 5OOV |
Interference | Power 2000V p-p |
Measuring Accuracy | 10.5°C |
Dielectric Strength | 1600V AC / 1 min |
Brand | WAROM International INC |
---|---|
Type Of Approval | ATEX/Zone Zone 2 |
Approval Code | LCIE 11 ATEX 3070 X |
Approval Body Name | BUREAU VERITAS (BV) |
Explosion Protection | Gas Explosion Protection |
Degree Of Protection | IP66 |
Ambient Temperature | -60°C to +55°C |
Enclosure Material | Copper Free Aluminium Powder Coated External Surface |
Exposed Fastener | Toughened Glass, Impact Resistance, High Light Transmission |
Mounting Lug | Stainless Steel |
Rated Voltage | 220-240 VAC 50/60 HZ 110 VAC 50/60 Hz |
Hinge | Integral Hinges Egg External Flange Enclosure; Stainless Steel Hinges For Internal Flange Enclosure |
Brand | WAROM International INC |
---|---|
Type Of Approval | ATEX/Zone Zone 2 |
Approval Code | LCIE 11 ATEX 3070 X |
Approval Body Name | BUREAU VERITAS (BV) |
Explosion Protection | *H 2 G Ex e BC T6 or TS Gb, *H 1 G Ex ia IIC T6 Ga, *H 2D Ex tb IIC T80't or T95't Ob IPGG |
Degree Of Protection | IP66 |
Ambient Temperature | Ex e: T6 for Tamb: -40°C to +40°C; TS for Tamb: -40°C to +50°C Ex ia: T6 for Tamb: -40°C to +50°C |
Enclosure Material | Stainless Steel |
Exposed Fastener | Stainless Steel |
Rated Voltage | Max 500 VAC |
Hinge | Integral Hinges For External Flange Enclosure; Stainless Steel Hinges For Internal Flange Enclosure |
Brand | WAROM International INC |
---|---|
Type Of Approval | ATEX/Zone Zone 2 |
Approval Code | LCIE 11 ATEX 3070 X |
Approval Body Name | BUREAU VERITAS (BV) |
Gas Explosion Protection | Ex H 2 G Ex d IC T6 Gb |
Dust Explosion Protection | Ex H 2 G Ex d IC80 T6 IPGb |
Enclosure | Copper-Free Aluminium, Powder Coated Surface, Yellow (RAL 1023) |
Transparent Cover | Toughened Glass, Stands 4) Impact |
Exposed Fastener | Stainless Steel |
Rated Voltage | 220-240V AC 50/60Hz; 24 DC/AC |
Lamp Specification | LED |
Lamp Power | SW |
Lamp Specification | LED |
Lamp Specification | LED |
Lamp Color | Red |
Flash Frequency | 150 (m/min) |
Sound Intensity | 100-1200 (R-1m) |
Earthing Protection | MS Ģinternal & External (arth Bolts) |
Degree of Protection | IP66 |
Ambient Temperature | -40°C 55°C |
Terminal | 3x1.5-2.5mm(L+N=PE] |